Product Identification

  • Manufacturer: Gefran.

  • Model: CIR-E-2-N-Z.

  • Ordering Code: F005790.

  • Product Series: CIR.

  • Product Type: Strain Gauge Transducer Amplifier.

Ordering Code Interpretation

  • CIR: Strain gauge amplifier series.

  • E: 4–20mA, two-wire current output.

  • 2: 2mV/V primary sensor sensitivity.

  • N: 700Ω measurement bridge resistance.

  • Z: Passing calibration configuration for six-wire strain gauge sensors.

Technical Specifications

  • Output Signal: 4–20mA, two-wire.

  • Supply Voltage: 12–30VDC.

  • Primary Sensor Sensitivity: 2mV/V.

  • Measurement Bridge Resistance: 700Ω ±10%.

  • Transducer Excitation Voltage, E Version: 0.9VDC.

  • Zero Output: 4mA.

  • Full-Scale Output: 20mA.

  • Zero Accuracy: Less than ±0.1% FSO.

  • Full-Scale Output Accuracy: Less than ±0.1% FSO.

  • Zero Adjustment: Greater than ±10% FSO.

  • Span Adjustment: Greater than ±10% FSO.

  • Response Time, 10–90% FSO: Approximately 6ms.

  • Typical Zero Thermal Drift: ±0.01% FSO/°C.

  • Typical Span Thermal Drift: ±0.01% FSO/°C.

  • Compensated Temperature Range: 0°C to +70°C.

  • Operating Temperature Range: -10°C to +80°C.

  • Storage Temperature Range: -50°C to +100°C.

  • Protection Rating: IP65.

  • Output Cable Length: 1m.

  • Case Material: Stainless steel / anodized aluminum.

 
gefran-online.com

Protection and Adjustment

  • Reverse-polarity protection.

  • Accidental short-circuit protection.

  • ZERO adjustment.

  • SPAN adjustment.

  • Calibration-wire support for six-wire sensors.

  • Screened cable connection.

Typical Applications

  • Load cell signal amplification.

  • Industrial force measurement.

  • Strain gauge pressure transducer interfacing.

  • Material tension monitoring with compatible sensors.

  • PLC analog signal acquisition.

Important Integration Notes

The CIR-E-2-N-Z is a signal-conditioning amplifier, not a standalone force or tension sensor. It requires a compatible strain gauge transducer.

The standard CIR series should not be assumed to provide the same galvanic isolation as the separately identified CIR-D series.