Product Identification

  • Manufacturer: Gefran S.p.A.

  • Model: M31-6-M-B07C-1-4-D 2130X000X00.

  • Ordering Code: F008611.

  • Product Series: M3.

  • Product Family: Mercury-filled M Series.

  • Product Type: Melt Pressure Transducer.

  • Configuration: Rigid stem with flexible capillary.

Measurement Specifications

  • Nominal Pressure Range: 0–700 bar.

  • Equivalent Pressure Range: 0–70 MPa.

  • Accuracy Class: M – 0.5% FS.

  • Declared Accuracy for Class M: Less than ±0.5% FS.

  • Maximum Process Media Temperature: +400°C.

  • Measurement Technology: Strain gauge Wheatstone bridge.

  • Pressure Transmission Principle: Hydraulic.

  • Pressure Transmission Fluid: Mercury (Hg).

Electrical Specifications

  • Nominal Output Signal: 3.33 mV/V.

  • Output Type: Unamplified low-level analog signal.

  • Electrical Connector: Six-pin.

  • Catalogue Connector Type: Veam VPT07RA10-6PT2 (PT02A-10-6P).

  • Internal Calibration Signal: R-Cal, 80% FS.

  • Protection Rating: IP65, six-pin connector version.

Mechanical Specifications

  • Process Connection: 1/2-20 UNF.

  • Rigid Stem Length: 153 mm (6 inches).

  • Flexible Capillary Length: 457 mm (18 inches).

  • Standard M3 Diaphragm Material for This Pressure Range: 15-5 PH stainless steel.

  • Standard Diaphragm Coating: GTP+, according to current manufacturer documentation.

  • Integrated Thermocouple: No.

Functional Features

  • High-temperature melt pressure measurement.

  • Hydraulic pressure transmission.

  • Low-level strain gauge bridge output.

  • Flexible capillary configuration.

  • Internal calibration signal.

  • Integration with compatible pressure measurement instrumentation.

Typical Applications

  • Plastic extrusion machinery.

  • Polymer melt processing.

  • Plastic pipe extrusion.

  • Plastic film manufacturing.

  • Plastic sheet manufacturing.

  • Polymer pelletizing systems.

  • Industrial high-temperature pressure monitoring.

Important Integration Notes

The 400°C temperature rating applies to the process medium and must not be interpreted as the permissible ambient temperature of the electrical housing.

The transducer requires compatible strain gauge signal-conditioning equipment. Its 3.33mV/V output must not be confused with standard amplified current or voltage outputs.

The M31 configuration does not include an integrated thermocouple.

Mercury-containing products must be handled and disposed of in accordance with applicable environmental and occupational safety regulations.

The product must only be selected for applications within the manufacturer's declared regulatory and installation scope.