Product Identification

  • Manufacturer: Vaisala Oyj.

  • Ordering Code: WXT530 6U1B1A1A1A1B.

  • Device Model: WXT536.

  • Product Series: WXT530 Series.

  • Product Type: Multiparameter Weather Transmitter.

  • Sensor Heating: Not included.

  • Communication: Wired serial communication.

Wind Speed Measurement – WINDCAP

  • Observation Range: 0–60 m/s.

  • Reporting Range: 0–75 m/s.

  • Accuracy: ±3% at 10 m/s.

  • Output Resolution: 0.1 m/s.

  • Response Time: 0.25 s.

  • Available Variables: Average, maximum and minimum.

  • Available Units: m/s, km/h, mph and knots.

Wind Direction Measurement

  • Measurement Range: 0–360°.

  • Accuracy: ±3° at 10 m/s.

  • Output Resolution: 1°.

  • Response Time: 0.25 s.

  • Configurable Averaging Time: 1–3,600 s.

  • Configurable Sampling Rate: 1, 2 or 4 Hz.

Precipitation Measurement – RAINCAP

  • Sensor Collecting Area: 60 cm².

  • Accumulated Rainfall Resolution: 0.01 mm.

  • Daily Rainfall Accumulation Accuracy: Better than 5%, weather-dependent.

  • Rainfall Duration Resolution: 10 s.

  • Rainfall Intensity Observation Range: 0–200 mm/h.

  • Rainfall Intensity Resolution: 0.1 mm/h.

  • Rainfall Intensity Calculation: Running one-minute average, updated in ten-second steps.

  • Additional Capability: Hail impact detection and reporting.

Barometric Pressure Measurement – BAROCAP

  • Observation Range: 500–1,100 hPa.

  • Sensor Element Accuracy: ±0.5 hPa at 0°C to +30°C, within 600–1,100 hPa.

  • Sensor Element Accuracy: ±1 hPa at -52°C to +60°C, within 600–1,100 hPa.

  • Output Resolution: 0.1 hPa.

  • Available Units: hPa, Pa, bar, mmHg and inHg.

Air Temperature Measurement

  • Observation Range: -52°C to +60°C.

  • Sensor Element Accuracy: ±0.3°C at +20°C.

  • Output Resolution: 0.1°C.

  • Available Units: °C and °F.

Relative Humidity Measurement – HUMICAP

  • Observation Range: 0–100% RH.

  • Sensor Element Accuracy: ±3% RH at 0–90% RH.

  • Sensor Element Accuracy: ±5% RH at 90–100% RH.

  • Output Resolution: 0.1% RH.

  • Configurable PTU Measurement Interval: 1–3,600 s.

Electrical and Communication Specifications

  • Nominal Operating Voltage: 6–24 VDC.

  • Supply Voltage Tolerance: -10% to +30%.

  • Typical Series Current Consumption: 3.5 mA at 12 VDC under typical measurement conditions.

  • Communication Interface: RS-485.

  • Communication Protocol: Modbus RTU Server.

  • Default Baud Rate: 19,200 bps.

  • Data Bits: 8.

  • Parity: Even.

  • Stop Bits: 1.

  • Default Modbus Address: 1.

  • Data Connector: Eight-pin male M12.

  • Service Connector: Four-pin M8.

  • Analog Interfaces: None.

  • Sensor Heating: None.

  • Startup Time: Less than five seconds to the first valid output.

Mechanical and Environmental Specifications

  • Nominal Weight: 0.7 kg.

  • Installation Environment: Outdoor.

  • Operating Temperature: -52°C to +60°C.

  • Storage Temperature: -60°C to +70°C.

  • Operating Humidity: 0–100% RH.

  • Protection Rating Without Mounting Kit: IP65.

  • Protection Rating With Mounting Kit: IP66.

  • Precipitation Sensor Plate: AISI 316 stainless steel.

  • Housing and Radiation Shield Material: Polycarbonate reinforced with 20% fiberglass.

Ordering Configuration

  • Model Version: WXT536.

  • User Profile: Standard.

  • Data Connector: M12 male, including bushing and grounding accessories.

  • Sensor Heating: Not included.

  • Connection Cable: Not included.

  • Installation Accessories: Not included.

  • Optional Configuration Software Package: Not included.

  • Manual: Online documentation.

  • Packaging: Standard packaging.

  • Documentation: Factory Test Reports.

Typical Applications

  • Automatic weather monitoring stations.

  • Industrial environmental monitoring.

  • Renewable energy projects.

  • Agricultural meteorology.

  • Marine and port environmental monitoring.

  • Building automation and HVAC systems.

  • Meteorological research.

  • Industrial SCADA and weather data acquisition.

Important Technical Notes

The WXT530 6U1B1A1A1A1B configuration does not include wireless communication, analog input/output interfaces or sensor heating.

The IP66 protection rating requires installation with the appropriate optional mounting kit.

Operating temperature limits must not be interpreted as a guarantee of unrestricted wind and precipitation measurement under icing conditions.

Factory Test Reports must not be advertised as accredited MEASNET wind calibration certificates.