Baumüller BM1425-01-00-01 is an industrial AC frequency converter belonging to the b maXX 1000 product family.

Manufacturer-Verified BM1425 Specifications:

  • Manufacturer: Baumüller

  • Product Family: b maXX 1000

  • Model: BM1425-01-00-01

  • Product Type: Frequency Converter / AC Inverter

  • Frame Size: 2

  • Typical Motor Power: 2.2 kW

  • Rated Output Current: 5.5 A

  • Maximum Output Current: 8.25 A

  • Overload Factor: 1.5

  • Overload Duration: 60 seconds

  • Input Supply: Three-phase 380–480 VAC ±10%

  • Supply Frequency: 47–63 Hz

  • Switching Frequency: 1–15 kHz

  • Adjustable Output Frequency: 0.1–400 Hz

  • Protection Rating: IP20

  • Dimensions, W × H × D: 100 × 174 × 152 mm

The published height and depth include mounting brackets. The depth does not include the required cable bending clearance.

Product-Family Features:

  • Vector control for standard AC motors.

  • Integrated standard EMC filter.

  • Drive monitoring and protection functions.

  • 15 preset speeds.

  • CANopen connectivity as described in the product-family documentation.

  • Published operating temperature range: -10°C to +50°C, subject to installation conditions; the upper limit may be reduced to +40°C when units are mounted closely together.

Product Identification:

  • Requested Model: BM1425-01-00-01

  • Distributor-Reported Article Number: 00399882

  • Supply Category: Three-phase 400V frequency converter.

Details Requiring Verification:

  • Manufacturer article number on the actual product nameplate.

  • Current production and stock availability.

  • Hardware and firmware revisions.

  • Communication configuration and included accessories.

  • Compatibility with an existing drive installation.

  • Applicable derating requirements.

Important: The 2.2kW value is the manufacturer's typical motor rating. Final drive selection must consider the motor's rated current, load characteristics and operating conditions.

Safety Notice: Hazardous voltage may remain in the DC-link capacitors after disconnection from the mains supply. Installation and maintenance must be performed by qualified personnel following the manufacturer's safety instructions.