Baumüller SET-BM4424-SI1-22642-S01-0315-7012-E80 is an industrial servo inverter set based on the BM4424 platform from the b maXX 4400 drive family.

Manufacturer-Verified BM4424 Base-Unit Specifications:

  • Manufacturer: Baumüller

  • Product Family: b maXX 4400

  • Base Drive: BM4424

  • Product Type: Servo Inverter / Servo Drive

  • Frame Size: 2

  • Rated Output Current: 15 A

  • Maximum Output Current: 30 A

  • Typical Motor Rating: 6.8 kW

  • Overload Factor: 2

  • Reference Dimensions, W × H × D: 106 × 428 × 340 mm / 320 mm, depending on cooling configuration

Additional BM4424 Universal-Unit Electrical Data:

  • Rated Input Apparent Power: 11.8 kVA

  • Rated Input Current: 17.0 A

  • Maximum Input Current: 31.8 A

  • Nominal DC-Link Voltage: 540 VDC

  • Internal DC-Link Capacitance: 705 µF

  • Internal DC-Link Discharge Time: 510 seconds

These additional specifications are published for the BM4424 universal-unit configuration. Their applicability to the exact SET assembly must be confirmed.

Third-Party Ordering-Code References:

  • Requested Code: SET-BM4424-SI1-22642-S01-0315-7012-E80

  • Similar Code 1: SET-BM4424 SL1-22642-S01-0315-7012-E80 – distributor-reported Article No. 06477640.

  • Similar Code 2: SET-BM4424-SI1-21642-S01-0315-7012-E80 – distributor-reported Article No. 06477639.

Configuration Details Requiring Verification:

  • Exact manufacturer article number.

  • Included drive modules and option cards.

  • Complete interpretation of the ordering suffix.

  • Actual cooling arrangement.

  • Encoder feedback and communication interfaces.

  • Integrated safety functions.

  • Hardware and firmware revisions.

  • Drive parameter datasets and replacement compatibility.

  • Final dimensions, weight and accessories.

Important: The similar ordering codes must not be treated as interchangeable without manufacturer confirmation.

The 6.8kW value is the manufacturer's typical motor rating for the BM4424 platform, not guaranteed output power under every operating condition.

Safety Notice: The DC link may retain hazardous electrical energy after power disconnection. Installation and maintenance must follow Baumüller's isolation and voltage verification procedures.