The following information combines HE102 series specifications with the manufacturer's ordering code documentation.

1. Product Identification

  • Manufacturer: HAUBER-Elektronik GmbH.

  • Model: HE102.01.4g.01.00.00.200.

  • Series: HE102.

  • Product Family: HE10x.

  • Product Type: Vibration Monitoring Unit.

  • Measured Quantity: Vibration acceleration RMS.

2. Measurement Specifications

  • Measuring Range: 0–4 g RMS.

  • Equivalent Measuring Range: Approximately 0–39.23 m/s² RMS.

  • Frequency Range: 1–1,000 Hz.

  • Series Accuracy: ±10% according to DIN ISO 2954.

  • Cross Sensitivity: Less than 5%.

  • Calibration Frequency: 159.2 Hz.

  • Calibration Amplitude: 90% of the measuring range.

  • Corresponding Calibration Value: 3.6 g RMS.

  • Series Maximum Acceleration: ±16.5 g.

3. Signal Processing

  • Measurement Evaluation: Acceleration RMS.

  • Reference Signal Processing: Exponentially time-weighted RMS.

  • Reference Averaging Time: 1.1 seconds.

  • Reference Settling Response: 99% after approximately 5.5 seconds.

The analogue output represents a processed RMS measurement rather than a raw dynamic acceleration waveform.

4. Analogue Output Specifications

  • Output Type: Analogue DC current.

  • Output Signal: 4–20 mA.

  • Number of Outputs: One.

  • Output Characteristic: Proportional to the configured acceleration measuring range.

  • Transmitter Design: Two-wire current loop.

  • Maximum Reference Output Load: 500 Ω.

Nominal Lower Scale Value: 4 mA at 0 g RMS.

Nominal Mid-Scale Value: 12 mA at 2 g RMS.

Nominal Upper Scale Value: 20 mA at 4 g RMS.

5. Electrical Specifications

  • Supply Voltage: 10–30 VDC.

  • Reference Nominal Supply Voltage: 24 VDC.

  • Maximum Current Consumption: 25 mA.

  • Power and Signal Connection: Two-wire current loop.

  • External Monitoring Compatibility: Suitable analogue input systems.

  • IO-Link Communication: Not part of the standard HE102 transmitter configuration.

6. Mechanical Specifications

  • Housing Material Code: 00.

  • Housing Material: Stainless steel 1.4305.

  • Material Designation: V2A.

  • Reference Equivalent Grade: AISI 303.

  • Mounting Type: External thread.

  • Mounting Thread: M8 × 8 mm.

  • Thread Pitch: 1.25 mm.

  • Reference Width Across Flats: 24 mm.

  • Reference Tightening Torque: 8 Nm.

  • Mounting Orientation: Horizontal or vertical.

  • Measuring Direction: Along the mounting axis.

7. Integrated Cable Specifications

  • Connection Configuration: Integrated cable.

  • Cable Length: 20 metres according to ordering suffix 200.

  • Reference Cable Type: 12YC11Y.

  • Cable Construction: Four conductors, 0.34 mm² each.

  • Core Insulation: TPE-E.

  • Outer Sheath Material: PUR.

  • Reference Outer Diameter: 6.0 ±0.2 mm.

  • Halogen-Free Construction: Yes.

8. Electrical Connection Identification

  • Brown Conductor: L+.

  • Blue Conductor: Current-loop output signal.

  • White Conductor: Not connected.

  • Black Conductor: Not connected.

Hazardous area electrical installation must comply with the applicable manufacturer instructions and certification requirements.

9. Environmental and Reliability Specifications

  • Reference Ambient Temperature: −40 to +60°C according to the operating manual.

  • Reference Measuring Head Temperature: −40 to +125°C according to the operating manual.

  • Reference Design Lifetime: 10 years.

  • Reference MTTF: 399 years.

The final permitted temperatures must be confirmed against the applicable Ex certification and device configuration. MTTF does not represent a guaranteed operating lifetime or warranty period.

10. Explosion Protection

  • Explosion Protection Configuration: HE102.01.

  • Gas Protection Method: Ex d / Ex db.

  • Dust Protection Method: Ex tb.

  • Gas Hazardous Areas: Zone 1 and Zone 2.

  • Dust Hazardous Areas: Zone 21 and Zone 22.

  • Reference Gas Marking: Ex II 2 G Ex db IIC T4 Gb.

  • Reference Dust Marking: Ex II 2 D Ex tb IIIC T120°C Db.

  • Gas Group: IIC.

  • Dust Group: IIIC.

  • Gas Temperature Class: T4.

  • Equipment Protection Level: Gb / Db.

  • Reference ATEX Certificate: PTZ 16 ATEX 0029 X Rev 4.

  • Reference UKEx Certificate: UL22UKEX2481X.

The certification references apply to the HE102.01 configuration group. The supplied device documentation must be verified before hazardous area commissioning.

11. Key Features

  • Continuous industrial acceleration RMS monitoring.

  • Measuring range of 0–4 g RMS.

  • Frequency coverage from 1 to 1,000 Hz.

  • Proportional 4–20 mA analogue output.

  • Two-wire transmitter technology.

  • Stainless steel V2A housing.

  • Integrated 20-metre connection cable.

  • Hazardous area configuration.

  • Suitable for industrial condition monitoring systems.

12. Industrial Applications

  • Electric motor vibration monitoring.

  • Industrial pump condition monitoring.

  • Fan and blower vibration monitoring.

  • Gearbox condition monitoring.

  • Compressor vibration monitoring.

  • Generator bearing monitoring.

  • Oil and gas rotating machinery.

  • Chemical processing equipment.

  • Cement and steel production machinery.