1. Product Identification

Manufacturer: HAUBER-Elektronik GmbH.

Model: HE205.01.4g.00.00.00.100.

Series: HE205.

Product Family: HE20x.

Product Type: Vibration Monitoring Unit.

Measured Quantity: Vibration acceleration RMS.

Monitoring Method: Window Function.

2. Measurement Specifications

Measuring Range: 0–4 g RMS.

Equivalent Measuring Range: Approximately 0–39.23 m/s² RMS.

Frequency Range: 10–1,000 Hz.

Reference Series Accuracy: ±10% according to DIN ISO 2954.

Cross Sensitivity: Less than 5%.

Calibration Frequency: 159.2 Hz.

Calibration Amplitude: 90% of the measuring range.

Corresponding Calibration Value: 3.6 g RMS.

Reference Maximum Acceleration: ±16.5 g.

3. Window Monitoring Function

Monitoring Channels: LIM1 and LIM2.

LIM1: Adjustable lower vibration limit.

LIM2: Adjustable upper vibration limit.

Window Area: Defined operating range between the lower and upper limits.

Lower Limit Alarm: Generated when the measured acceleration falls below the lower limit.

Upper Limit Alarm: Generated when the measured acceleration exceeds the upper limit.

Alarm Delay: Independently adjustable for the corresponding monitoring limits.

The window monitoring function differs from conventional two-stage upper threshold monitoring.

4. Analogue Output Specifications

Output Type: Analogue DC current output.

Number of Analogue Outputs: One.

Output Signal: 4–20 mA.

Output Characteristic: Proportional to the acceleration RMS measuring range.

Maximum Reference Output Load: 500 Ω.

Nominal Lower Scale Value: 4 mA at 0 g RMS.

Nominal Mid-Scale Value: 12 mA at 2 g RMS.

Nominal Upper Scale Value: 20 mA at 4 g RMS.

The nominal output values do not represent individual calibration results.

5. Switching Output Specifications

Number of Switching Outputs: Two.

Output Design: Potential-free switching outputs.

Switching Channel 1: Lower limit monitoring.

Switching Channel 2: Upper limit monitoring.

Limit Values: Adjustable.

Delay Times: Adjustable.

Reference Switching Load in the 2021 manual: 1 A / 30 VDC.

Sensor Version 2.0: Potential-free semiconductor switches according to the 2025 operating instructions.

The applicable switching load and output characteristics must be verified against the actual hardware revision.

6. Electrical Specifications

Reference Supply Voltage: 24 VDC ±10%.

Equivalent Supply Range: 21.6–26.4 VDC.

Reference Maximum Current Consumption: 100 mA according to the 2021 manual.

Analogue Signal: 4–20 mA.

Additional Outputs: Two switching channels.

Reference Maximum Analogue Load: 500 Ω.

Connection Design: Dedicated power supply and signal conductors.

The HE205 is not a conventional two-wire current-loop transmitter.

7. Functional Safety Specifications

Safety Integrity Level: SIL 2.

Performance Level: PL-d.

Reference Functional Safety Standard: IEC 61508.

Hardware Assessment: TÜV Süd according to the operating instructions.

Reference Safety Architecture: 1oo1 with diagnostics.

Diagnostic Coverage: Greater than 90%.

Safe Failure Fraction: 90% to below 99%.

Reference Operating Mode: High-demand system.

Diagnostic Function: Automatic diagnostics during start-up and operation.

The complete machinery safety function must be independently designed and validated in accordance with the applicable Safety Manual.

8. Fail-safe Function

The sensor enters its defined fail-safe state when an internal fault cannot be automatically corrected.

The published version 2.0 fail-safe indications include illuminated status LEDs, open switching outputs and a 0 mA analogue signal.

The 0 mA fault indication must be distinguished from the normal 4 mA lower-scale measurement signal.

9. Mechanical Specifications

Housing Material Code: 00.

Housing Material: Stainless steel 1.4305.

Material Designation: V2A.

Reference Equivalent Grade: AISI 303.

Connection Type: Integrated cable.

Cable Length: 10 metres.

Metal Protection Hose Adaptation: Not included in the standard housing code 00.

10. Integrated Cable Specifications

Connection Code: 100.

Cable Configuration: Integrated cable.

Cable Length: 10,000 mm.

Connection Functions: Power supply, analogue output and two switching output channels.

Reference Version 2.0 Cable Configuration: Eight conductors.

Electrical installation must follow the applicable manufacturer documentation for the supplied device version.

11. Environmental Specifications

Configured Measuring Head Temperature Range: −40 to +85°C.

Reference Ambient Temperature Range: −40 to +60°C.

Series Protection Rating: IP66/IP67.

Reference Design Lifetime: 10 years according to the 2021 manual.

Permitted environmental conditions remain subject to the applicable explosion protection documentation.

12. Explosion Protection

Explosion Protection Configuration: HE205.01.

Approvals: ATEX / IECEx.

Gas Hazardous Area Configuration: Zone 1.

Dust Hazardous Area Configuration: Zone 21.

Gas Protection Method: Ex db.

Dust Protection Method: Ex tb.

Published Gas Marking Reference: II 2G Ex db IIC T4 Gb.

Published Dust Marking Reference: II 2D Ex tb IIIC 135°C Db.

Gas Group: IIC.

Dust Group: IIIC.

Gas Temperature Class: T4.

Equipment Protection Level: Gb / Db.

Reference ATEX Certificate: UL 20 ATEX 2421 X Rev. 0.

Reference IECEx Certificate: IECEx ULD 20.0022X.

Final certification validity and special conditions of use must be verified against the actual equipment documentation.

13. Reference Standards and Directives

IEC 61508 – Functional safety.

DIN ISO 2954 – Requirements for vibration severity measuring instruments.

DIN ISO 10816 – Machine vibration evaluation.

EN IEC 60079-0 – General requirements for explosive atmospheres.

EN 60079-1 – Flameproof enclosure protection.

EN 60079-31 – Dust ignition protection by enclosure.

2014/34/EU – ATEX Directive.

2014/30/EU – EMC Directive.

2011/65/EU – RoHS Directive.

14. Key Features

Continuous vibration acceleration RMS monitoring.

Measuring range of 0–4 g RMS.

Frequency coverage from 10 to 1,000 Hz.

Proportional 4–20 mA analogue output.

Two adjustable limit monitoring channels.

Window Function for lower and upper vibration limit detection.

Adjustable alarm delay times.

Automatic diagnostics and fail-safe functionality.

SIL 2 / PL-d functional safety capability.

Stainless steel V2A housing.

Integrated 10-metre connection cable.

ATEX/IECEx hazardous area configuration.

15. Industrial Applications

Electric motor vibration monitoring.

Industrial pump condition monitoring.

Compressor vibration monitoring.

Fan and blower protection.

Gearbox condition monitoring.

Turbine vibration monitoring.

Generator bearing monitoring.

Oil and gas rotating machinery.

Chemical processing equipment.

Power generation facilities.

Cement and steel manufacturing machinery.

Industrial functional safety systems.

Machinery protection and condition monitoring systems.