Type
|
Model Specification
|
Model
|
Catalog
|
Display Gauge
|
Anti-corrosion pressure gauge_P870 series
Nominal diameter: 50 mm
Accuracy: ±1.5 % of full scale (Only available with 0.6 and 1 MPa) ±2.0 % of full scale
Scale range (MPa, kPa, bar): 0 ~ 0.1 MPa to 0 ~ 1 MPa
Working pressure: Steady pressure : 75 % of full scale
Working temperature limits: Ambient : 10 ~ 30 °C
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately
±0.8 % per 10 ℃ of full scale
|
Model P870
-Wise Control Vietnam
|
|
Display Gauge
|
High purity pressure gauge (BA grade)_P830 series (316L type)
Nominal diameter:35 (1½"), 50 (2") and 63 mm (2½")
Accuracy: Grade A : 50 (2") and 63 mm (2½")
Grade B : 35 (1½"), 50 (2") and 63 mm (2½")
Scale range (MPa, kPa, bar): -0.1 ~ 0 to 0 ~ 28 MPa
Working pressure:Steady pressure : 75 % of full scale value
Fluctuating pressure : 67 % of full scale value
Working temperature limits: Ambient : -40 ~ 65 °C
Fluid : Max. 100 °C
Temperature effect:Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately±0.4 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P830
-Wise Control Vietnam
|
|
Display Gauge
|
Ultra high purity pressure gauge (EP grade)_P820 series (316L type double melt)
Nominal diameter: 50 (2") and 63 mm (2½")
Accuracy: Grade A (ASME B40.1) : 50 (2") and 63 mm (2½")
Grade B (ASME B40.1) : 50 (2") and 63 mm (2½")
Scale range (MPa, kPa, bar):-0.1 ~ 0 to 0 ~ 28 MPa
Working pressure:Steady pressure : 75 % of full scale value
Fluctuating pressure : 67 % of full scale value
Working temperature limits:Ambient : -40 ~ 65 °C
Fluid : Max. 100 °C
Temperature effect:Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.4 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P820
-Wise Control Vietnam
|
|
Display Gauge
|
Ultra high purity pressure gauge (EP grade)_P810 series (316L type)
Nominal diameter:35 (1½"), 50 (2") and 63 mm (2½")
Accuracy: Grade A : 50 (2") and 63 mm (2½")
Grade B : 35 (1½"), 50 (2") and 63 mm (2½")
Scale range (MPa, kPa, bar):-0.1 ~ 0 to 0 ~ 28 MPa
Working pressure: Steady pressure : 75 % of full scale value
Fluctuating pressure : 67 % of full scale value
Working temperature limits: Ambient : -40 ~ 65 °C
Fluid : Max. 100 °C
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.4 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P810
-Wise Control Vietnam
|
|
Display Gauge
|
Diaphragm seal for Pressure Instrument_P790 series
Design: Instrument welded diaphragm with threaded process connection, require hydraulic fluid to transmitter pressure to instrument.
Filling liquid: Silicone oil
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Refer to filling liquid reference table
Diaphragm material: Diaphragms are available in many corrosion resistant materials. Compatibility of selected material and process fluid should be determined by the user
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P790
-Wise Control Vietnam
|
|
Display Gauge
|
Diaphragm pressure gauge with dry type_P770 series
Nominal diameter: 100 and 160 mm
Accuracy: ±1.6% of full scale
Scale range (MPa, kPa, bar): 0 ~ 1 kPa to 0 ~ 40 kPa (Flange 150 mm)
0 ~ 50 kPa to 0 ~ 2.5 MPa (Flange 100 mm)
Working pressure: Steady : Full scale value
Fluctuating : 90 % of full scale value
Over range protection: Overpressure safety 130 % of full scale value
Overpressure safety 500 % of full scale value, Max. 5 MPa (Option)
Opton : Overpressure safety 500 % of full scale value, Max. 5 MPa
Working temperature limits: Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately
±0.8 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P770
-Wise Control Vietnam
|
|
Display Gauge
|
Pressure gauge with diaphragm seal_P761,P762,P763
Design: Internal diaphragm
Accuracy: Refer to gauge model
Suitable pressure range (MPa, kPa, bar): -0.1 ~ 0 to -0.1 ~ 2.5 MPa
0 ~ 0.1 to 0 ~ 35 MPa
Filling liquid: Silicone oil
Working temperature: Temperature rating of the diaphragm seals depends on the fill fluid, the diaphragm material and the lower housing material. Standard fill fluids are available for temperature range -20 ~ 200 ˚C
Diaphragm material: Diaphragms are available in many corrosion resistant materials. Compatibility of selected material and process fluid is the responsibility of user
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ˚C) will be effected by approximately
±0.5 % per 10 ˚C of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P761,P762,P763
-Wise Control Vietnam
|
|
Display Gauge
|
Flush diaphragm type pressure gauge_P757 series
Nominal diameter: 63, 80 and 100 mm
Accuracy: 63 and 80 mm : ±1.6 % of full scale 100 mm : ±1.0 % of full scale
Scale range (MPa, kPa, bar): Refer to pressure unit and range table
Depending on diaphragm size and process conditions
Working pressure: Steady : 75 % of full scale
Over range protection : 130 % of full scale
Working temperature: Ambient : -20 ~ 65 °C Fluid : Max. 100 °C
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P757
-Wise Control Vietnam
|
|
Differential gauge
|
Low differential pressure gauge_P880 series
Nominal diameter: 100 mm
Accuracy: ±2.0 % of full scale
-5 ~ 5, -25 ~ 25 and 0 ~ 10 mm : ±3.0 % of full scale
0 ~ 3000 mm : ±4.0 % of full scale
Scale range (kPa): -0.25 to 0.25 kPa, 0~50 kPa
Working pressure: Steady pressure : 75 % of full scale
Over pressure protection : 100 kPa
Working temperature: Ambient : -10 ~ 60°C
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±1.0 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P880
-Wise Control Vietnam
|
|
Differential gauge
|
Differential pressure gauge with inductive contact type_P690 series
Nominal diameter: 160 mm
Accuracy: ±1.6 % of full scale
Scale range (MPa, kPa, bar, mbar): 0 ~ 25 kPa to 0 ~ 0.25 MPa
0 ~ 0.4 MPa to 0 ~ 2 MPa
Static pressure: Max. 10 MPa
Working temperature: Ambient : -20 ~ 65 °C -40 ~ 65 °C (With silicone filling)
Fluid : Max. 100 °C
Degree of protection: EN60529/IEC529/IP65
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P690
-Wise Control Vietnam
|
|
Differential gauge
|
Differential pressure gauge with reed switch_P680 series
Nominal diameter: 150 mm
Accuracy: ±1.0 % of full scale ±1.5 % of full scale
Scale range (MPa, kPa, bar, mbar): 0 ~ 25 kPa to 0 ~ 0.25 MPa (P681 model)
0 ~ 0.4 MPa to 0 ~ 2.0 MPa (P682 model)
Static pressure: Max. 10 MPa
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C
Degree of protection: EN60529/IEC529/IP65
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P680
-Wise Control Vietnam
|
|
Differential gauge
|
Differential pressure gauge with bellows element_P670 series
Nominal diameter: 100 and 160 mm
Accuracy: ±1.0 % of full scale ±1.6 % of full scale
Scale range (MPa, kPa, bar): 0 ~ 4 kPa, 6 kPa, 10 kPa (P671 model)
0 ~ 25 kPa to 0 ~ 0.25 MPa (P672 model)
0 ~ 0.4 MPa to 0 ~ 2.0 MPa (P673 model)
Static pressure: P671 : Max. 4 MPa P672 and P673 : Max. 10 MPa
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C
Degree of protection: EN60529/IEC529/IP67
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P670
-Wise Control Vietnam
|
|
Differential gauge
|
Differential pressure gauge with diaphragm element_P660 series
Nominal diameter: 100 and 160 mm
Accuracy: ±1.0 % of full scale ±1.6 % of full scale
Scale range (MPa, kPa, bar, mbar): 0 ~ 4 kPa to 0 ~ 40 kPa
Flange size / DN 140, Max. static / 10 and 25 MPa
0 ~ 60 kPa to 0 ~ 2.5 MPa
Flange size / DN80, Max. static / 25 MPa
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C
Degree of protection: EN60529/IEC529/IP65
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P660
-Wise Control Vietnam
|
|
Differential gauge
|
Differential pressure gauge with electrical contact type_P650 series
Nominal diameter: 160 mm
Accuracy: ±1.0 % of full scale ±1.6 % of full scale
Scale range (MPa, kPa, bar, mbar): 0 ~ 25 kPa to 0 ~ 0.25 MPa (P651 model)
0 ~ 0.4 MPa to 0 ~ 2.0 MPa (P652 model)
Static pressure: Max. 10 MPa
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C
Degree of protection: EN60529/IEC529/IP65
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P650
-Wise Control Vietnam
|
|
Differential gauge
|
Indicating type differential pressure switch with bellows element_P640 series
Nominal diameter: 150 mm
Accuracy: ±1.0 % of full scale ±1.5 % of full scale
Scale range (MPa, kPa, bar, mbar): 0 ~ 25 kPa to 0 ~ 0.25 MPa (P641 model)
0 ~ 0.4 MPa to 0 ~ 2.0 MPa (P642 model)
Static pressure: Max. 10 MPa
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C
Degree of protection: EN60529/IEC529/IP65
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P640
-Wise Control Vietnam
|
|
Differential gauge
|
Differential pressure gauge_P620, P630 series
Nominal diameter: 100 and 160 mm
Accuracy : ±1.0 % of full scale ±1.6 % of full scale
Scale range (MPa, kPa, bar): 0 ~ 1 kPa to 0 ~ 50 kPa
0 ~ 0.1 MPa to 0 ~ 1.5 MPa
Static pressure: P620 : 5 MPa P630 : 25 MPa
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C
Degree of protection: EN60529/IEC529/IP67
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P620, P630
-Wise Control Vietnam
|
|
Sanitary Gauges
|
Ultra high purity pressure transmitter_PT850 series
Technology: Piezo resistive effet sensor
Accuracy: ±0.25 % of full scale
Operating temperature range: -20 ~ 80 °C
Scale range: Refer to range code
Enclosure rating: IP 67
Explosion protection: Ex d IIC T6 (Model : PT850)
Ex ia IIC T4 (Model : PT851)
Ex nA IIC T4 (Model : PT852)
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P850
-Wise Control Vietnam
|
|
Sanitary Gauges
|
Ultra high purity pressure gauge with transmitter_PT840 series
Nominal diameter: 50 mm (2")
Gauge accuracy: ±1.0 % of full scale
Transmitter accuracy: ±0.25 % of full scale
Scale range: Refer to range code
Working pressure: Steady pressure : 75 % of full scale value
Fluctuating pressure: 67 % of full scale value
Working temperature: Ambient : -40 ~ 65
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.4 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P840
-Wise Control Vietnam
|
|
Sanitary Gauges
|
Ultra high purity pressure switch_P840 series (316L type)
Nominal diameter: 50 mm (2")
Switch point accuracy: ±2.0 % of full scale
Scale range: 0 ~ 28 MPa
Working pressure: Steady pressure : 75 % of full scale value
Fluctuating pressure: 67 % of full scale value
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.4 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P840
-Wise Control Vietnam
|
|
Sanitary Gauges
|
Sanitary pressure gauge - Male connection (3-A marking)_P753S series
Special features: 3-A certificated
Suitable for SIP and CIP
All stainless steel and welded construction
Nominal diameter: 63 and 100 mm
Accuracy: ±1.6 % of full scale
If scale range less than 100 psi : ±2.0% of full scale
Scale range: 0 ~ 3.5 MPa, single
Working pressure: Steady pressure : 75 % of full scale value
Fluctuating pressure : 67 % of full scale value
Operating temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 121 °C
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P753S
-Wise Control Vietnam
|
|
Sanitary Gauges
|
Sanitary pressure gauge (3-A marking)_P752S series
Special features: 3-A certificated
Suitable for SIP and CIP
All stainless steel and welded construction
Nominal diameter: 50, 63, 80 and 100 mm
Accuracy: P752 (50 mm) : ±3.0 % of full scale
P752 (63 mm) and P752 (80 mm) : ±1.6 % of full scale
P752 (100 mm): ±1.0 % of full scale
Scale range: -0.1 ~ 7 MPa
Working pressure: Steady pressure : 75 % of full scale value
Fluctuating pressure : 67 % of full scale value
Working temperature: Ambient : -25 ~ 65 °C
Fluid : Max.121 °C
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P752S
-Wise Control Vietnam
|
|
Sanitary Gauges
|
Sanitary pressure gauge_P750 series
Nominal diameter: 63, 80 and 100 mm
Accuracy: 63 and 80 mm : ±1.6 % of full scale 100 mm : ±1.0 % of full scale
Pressure range (MPa, kPa, bar): Steady : 75 % of full scale (63 and 80 mm) 100 % of full scale (100 mm)
Over range protection : 130 % of full scale
Working pressure: Steady : 75 % of full scale
Over range protection : 130 % of full scale
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 121 °C
Temperature effect: Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P750
-Wise Control Vietnam
|
|
Switch/Recorder
|
Explosion proof type differential pressure switch (Up to 20 kPa)_P991 series
Fluid: Air and gas
Repeatability: ±1.5 % of full range
Dead band: Fixed. 0.25 ~ 0.8 kPa or less
Differential pressure range (kPa): 0 ~ 4 kPa to 0 ~ 20 kPa
Static pressure: 500 kPa
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 60 °C
Degress of protection: EN60529/IEC529/IP65
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P991
-Wise Control Vietnam
|
|
Switch/Recorder
|
Explosion proof type indicating pressure switch (125 mm)_P990 series
Nominal diameter: 125 mm
Accuracy Indicator : ±1.0 % of full sacle
Switch setting : ±3 % of full sacle
Repeatability: ±1.0 % of adjustable range
Adjustable range (MPa, kPa, bar) -0.1 ~ 0 to -0.1 ~ 2 MPa
0 ~ 0.1 to 0 ~ 40 MPa
Switch differential: Fixed, less than 6 ~15 % of full sacle
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C
Temperature effect: Accuracy at temperature above and below the reference temperature (20 °C) will be effected by approximately ±0.4 % per 10 °C of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P990
-Wise Control Vietnam
|
|
Switch/Recorder
|
Explosion proof type indicating pressure switch (100 mm)_P980 series
Nominal diameter: 100 mm
Accuracy Indicator : ±1.0 % of full scale
Alarm setting : ±3.0 % of full scale
Repeatability: ±1.0 % of adjustable range (Micro contact type)
Adjustable range (MPa, kPa, bar): -0.1 ~ 0 to 0 ~ 2 MPa
0 ~ 0.1 to 0 ~ 35 MPa
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C
Temperature effect: Accuracy at temperature above and below the reference temperature (20 °C) will be effected by approximately ±0.4 % per 10 °C of full scale
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P980
-Wise Control Vietnam
|
|
Switch/Recorder
|
Explosion proof type differential pressure switch_P970 (953 series)
Fluid: Gas and oil
Repeatability: ±1.0 % of adjustable range
Adjustable range (mbar, kPa, bar, MPa): 15 kPa to 0.4 MPa
Dead band: Fixed
One SPDT : Approx. 5 % of adjustable range
Two SPDT : Approx. 10 % of adjustable range
Working temperature: Ambient : -40 ~ 65 °C
Fluid : Max. 100 °C
Static pressure: Max. 0.2, 5 MPa
Degree of protection: EN60529/IEC529/IP65
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P970
-Wise Control Vietnam
|
|
Switch/Recorder
|
Explosion proof pressure switch_P953 (953 series)
Fluid: Gas and oil
Repeatability: ±1.0 % of adjustable range
Adjustable range (mbar, kPa, bar, MPa) : 0.3 kPa to 15 MPa
-0.1 ~ -0.15 bar to 15 MPa
Dead band: Fixed
One SPDT : Approx. 5 % adjustable range
Two SPDT : Approx. 10 % of adjustable range
Working temperature: Ambient : -40 ~ 65 °C
Fluid : Max. 100 °C
Degree of protection: EN60529/IEC529/IP65
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P953
-Wise Control Vietnam
|
|
Switch/Recorder
|
Adjustable dead band weatherproof type pressure switch_P947
Fluid: Gas and oil
Repeatability: ±1.0 % of adjustable range
Adjustable range (mbar, kPa, bar, MPa):-0.1 ~ - 0.15 bar to 1.5 ~ 15 MPa
Dead band: Within 8 to 20 % of adjustable range
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C
Degree of protection: EN60529/IEC529/IP65
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P947
-Wise Control Vietnam
|
|
Switch/Recorder
|
Weatherproof type differential pressure switch_P946 series
Fluid: Gas and oil
Repeatability: ±1.0 % of adjustable range
Adjustable range (mbar, kPa, bar, MPa) :15 kPa to 0.4 MPa
Dead band: Fixed
One SPDT : Approx. 5 % of adjustable range
Two SPDT : Approx. 10 % of adjustable range
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C
Degree of protection: EN60529/IEC529/IP65
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P946
-Wise Control Vietnam
|
|
Switch/Recorder
|
Weatherproof type pressure switch_P945 series
Fluid: Gas and oil
Repeatability: ±1.0 % of adjustable range
Adjustable range (mbar, kPa, bar, MPa): -0.1 to -0.15 bar
Dead band: Fixed
One SPDT : Approx. 5 % of adjustable range
Two SPDT : Approx. 10 % of adjustable range
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C
Degree of protection: EN60529/IEC529/IP65
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P945
-Wise Control Vietnam
|
|
Switch/Recorder
|
Weatherproof type pressure switch (Local setpoint adjustable)_P940 series
Nominal diameter: Refer to dimension drawing
Repeatability: ±1.0 % of adjustable range
Adjustable setting range (MPa, kPa, bar): -0.1 ~ 0 to -0.1 ~ 2.5 MPa
0 ~ 0.1 to 0 ~ 35 MPa
Dead band: Fixed
One SPDT : Approx. 5 % adjustable range
Two SPDT : Approx. 10 % of adjustable range
Working temperature: Ambient : -20 ~ 65 °C
Fluid : Max. 100 °C
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P940
-Wise Control Vietnam
|
|
Switch/Recorder
|
Chart recorder_P930 series
Nominal diameter: 246 (W) X 271 mm (H)
Accuracy:±2.0 % of full scale
Scale range (MPa, kPa, bar): Pressure : 0 ~ 5 kPa to 0 ~ 100 MPa
Working pressure: Steady pressure : 75 % of full scale
Over range protection : 130 % of full scale
Working temperature: Ambient : -40 ~ 65 ℃
Fluid : Max. 200 ℃
Marker/ Origin: Wise Control_100% Korea Origin
|
Model P930
-Wise Control Vietnam
|
|
Transmitter
|
Absolute pressure transmitter_SMT2003
Accuracy: ±0.05 % of calibrated span. ±0.075 % of calibrated span ±0.1 % of calibrated span.
Range limits: 0 ~ 40 kPa to 0~30 bar
Turn down: Adjustable up to 100:1 range ability
Temperature compensation: High sensitivity temperature sensor packaged in the sensor
Isolating diaphragm: Stainless steel 316L / Hastelloy C
Measurement medium: Gas, Steam and liquid
Stability: 10 years stability
0.15 % of URL
Output: 4 ~ 20 mA with HART protocol
Marker/ Origin: Wise Control_100% Korea Origin
|
Model SMT2003
-Wise Control Vietnam
|
|
Transmitter
|
Gauge pressure transmitter_SMT2002
Accuracy: ±0.05 % of calibrated span. ±0.075 % of calibrated span.
±0.1 % of calibrated span.
Range limits: 0 ~ 6 kPa to 0∼40 MPa
Turn down: Adjustable up to 100:1 range ability
Temperature compensation: High sensitivity temperature sensor packaged in the sensor
Isolating diaphragm: Stainless steel 316L / Hastelloy C
Measurement medium: Gas, steam and liquid
Stability: 10 years stability 0.15 % of URL
Output: 4 ~ 20 mA with HART protocol
Marker/ Origin: Wise Control_100% Korea Origin
|
Model SMT2002
-Wise Control Vietnam
|
|
Transmitter
|
Differential pressure transmitter_SMT2001
Accuracy: ±0.05 % of calibrated span. ±0.075 % of calibrated span.
±0.1 % of calibrated span.
Range limits: 0 ~ 100 MPa to 0∼3 MPa
Turn down: Adjustable up to 100:1 range ability
Temperature compensation: High sensitivity temperature sensor packaged in the sensor
Isolating diaphragm: Stainless steel 316L / Hastelloy C / Tantalum
Stainless steel 316L with gold plated
Stainless steel 316L with FEP plated
Measurement medium: Gas, steam and liquid
Stability: 10 years stability
0.15 % of URL
Output: 4 ~ 20 mA with HART protocol
Marker/ Origin: Wise Control_100% Korea Origin
|
Model SMT2001
-Wise Control Vietnam
|
|
Thermometer
|
Remote reading thermometer with electrical contact_T761(H), T762(H/L), T763(L), T764(H/HH)
Nominal diameter: 100 mm
Accuracy: ±2.0 % of full scale
Measuring system (SAMA class ⅢB): Organic gas : 0 ~ 200 °C
Inert gas : -200 ~ 700 °C
Working range: Maximum scale value
Marker/ Origin: Wise Control_100% Korea Origin
|
Model T761(H), T762 (H/L),T763(L), T764(H/HH)
-Wise Control Vietnam
|
|
Thermometer
|
Bimetal thermometer with electrical contact_T751(H), T752(H/L), T753(L), T754(H/HH)
Nominal diameter: 100 mm
Accuracy: ±2.0 % of full scale
Temperature element: Coiled bimetal
Working range: Maximum scale value
Marker/ Origin: Wise Control_100% Korea Origin
|
Model 751(H), T752(H/L), T753(L), T754(H/HH)
-Wise Control Vietnam
|
|
Thermometer
|
Direct reading aluminium case thermometer with electrical contact_T721(H), T722(H/L), T723(L), T724(H/HH)
Nominal diameter: 100 mm
Accuracy: ±2.0 % of full scale
Measuring system (SAMA class ⅢB): Organic gas : 0 ~ 200 °C
Inert gas : -200 ~ 700 °C
Working range: Maximum scale value
Marker/ Origin: Wise Control_100% Korea Origin
|
Model T721(H), T722(H/L), T723(L), T724(H/HH)
-Wise Control Vietnam
|
|
Thermometer
|
Remote reading aluminium case thermometer with electrical contact_T711(H), T712(H/L), T713(L), T714(H/HH)
Nominal diameter: 100 and 150 mm
Accuracy: ±2.0 % of full scale
Measuring system (SAMA class ⅢB): Organic gas : 0 ~ 200 °C
Inert gas : -200 ~ 700 °C
Working range: Maximum scale value
Marker/ Origin: Wise Control_100% Korea Origin
|
Model T711(H), T712(H/L), T713(L), T714(H/HH)
-Wise Control Vietnam
|
|
Thermometer
|
Euro gauge Electrical contact type bimetal temperature gauge_T531(H), T532(H/L), T533(L), T534(H/HH), T535(L/LL), T536(H/L)
Nominal diameter: 100 mm
Accuracy: ±2.0 % of full scale
Temperature element: Coiled bimetal
Working range: Maximum scale value
Marker/ Origin: Wise Control_100% Korea Origin
|
Model T531(H), T532(H/L), T533(L), T534(H/HH), T535(L/LL), T536(H/L)
-Wise Control Vietnam
|
|
Thermometer
|
Euro gauge Electrical contact type temperature gauge_T521(H), T522(H/L), T523(L), T524(H/HH), T525(L/LL), T526(H/L)
Nominal diameter: 100 mm
Accuracy: ±2.0 % of full scale
Measuring system (SAMA class ⅢB): Organic gas : 0 ~ 200 °C
Inert gas : -200 ~ 700 °C
Working range: Maximum scale value
Marker/ Origin: Wise Control_100% Korea Origin
|
Model T521(H), T522(H/L), T523(L), T524(H/HH), T525(L/LL), T526(H/L)
-Wise Control Vietnam
|
|
Thermometer
|
Euro gauge Inductive contact type bimetal temperature gauge_T511(H), T512(H/L), T513(L), T514(H/HH), T515(L/LL)
Nominal diameter: 100 and 160 mm
Accuracy: ±2.0 % of full scale
Temperature element: Coiled bimetal
Working range: Maximum scale value
Marker/ Origin: Wise Control_100% Korea Origin
|
Model T511(H), T512(H/L), T513(L), T514(H/HH), T515(L/LL)
-Wise Control Vietnam
|
|
Thermometer
|
Euro gauge Inductive contact type temperature gauge_T501(H), T502(H/L), T503(L), T504(H/HH), T505(L/LL)
Nominal diameter : 100 and 160 mm
Accuracy : ±2.0 % of full scale
Measuring system (SAMA class ⅢB) : Organic gas : 0 ~ 200 °C
Inert gas : -200 ~ 700 °C
Working range:Maximum scale value
Marker/ Origin: Wise Control_100% Korea Origin
|
Model T501(H), T502(H/L), T503(L), T504(H/HH), T505(L/LL)
-Wise Control Vietnam
|
|
Thermometer
|
Glass thermometer_T400
Form: Rectangular
Accuracy: ±2.0 % of full scale
Measuring system: Liquid filled : 0 ~ 600 °C
Working range: Maximum scale value
Marker/ Origin: Wise Control_100% Korea Origin
|
Model T400
-Wise Control Vietnam
|
|
Thermometer
|
Safety pattern type remote reading thermometer solid-front turret style thermoplastic case_T360
Nominal diameter: 125 mm
Accuracy: ±2.0% of full scale
Measuring system (SAMA class ⅢB): Organic gas : 0 ~ 200 °C
Inert gas : -200 ~ 700 °C
Working range: Maximum scale value
Marker/ Origin: Wise Control_100% Korea Origin
|
Model T360
-Wise Control Vietnam
|
|
Thermometer
|
Safety pattern type direct reading thermometer solid-front turret style thermoplastic case_T359
Nominal diameter: 125 mm
Accuracy: ±2.0 % of full scale
Measuring system (SAMA class ⅢB): Organic gas : 0 ~ 200 °C
Inert gas : -200 ~ 700 °C
Working range: Maximum scale value
Marker/ Origin: Wise Control_100% Korea Origin
|
Model T359
-Wise Control Vietnam
|
|
Thermocouple
|
Field junction box_B500 series
Certificates ATEX
- II 2G Ex d ia/ib IIC T6 Gb
- II 2G Ex e IIC T6 Gb
- II 2D Ex tb IIIC T85 ˚C Db
IECEx
- Ex d ia/ib IIC T6 Gb
- Ex e IIC T6 Gb
- Ex tb IIIC T85 ˚C Db
Marker/ Origin: Wise Control_100% Korea Origin
|
Model B500
-Wise Control Vietnam
|
|
Thermocouple
|
Explosion proof type space heater_H100 series
Usage: Used to prevent freezing of electric motor and to maintain the temperature of specific space or area
Safety and environment: This product is not designed to use the controller to control temperature. Instead, the temperature can be controlled by changing voltage (V) and wattage (W) on the space heater. Therefore, it is critical to check the voltage and the wattage indicated on the product before installation. This product is made of environment-friendly and harmless materials to human body. Please dismantle the product before discarding.
Heating element: Ni-Cr (Standard) Fe-Cr Kantal
Tube material 304SS
Standard: Explosive atmospheres. Equipment. General requirements
■ EN 60079-0:2009
Electrical apparatus for explosive gas atmospheres. Increased safety "e"
■ EN 60079-7:2007
Temperature effect: Accuracy at temperature above and below the reference temperature (20℃) will be effected by approximately ±1.0% per 10℃ of full scale
Ambient temperature: Tamb = -40 ~ 70 ℃
Certificates: KCS Ex e II
ATEX II 2G Ex e II Gb
IECEx Ex e IIC Gb
Marker/ Origin: Wise Control_100% Korea Origin
|
Model H100
-Wise Control Vietnam
|
|
Thermocouple
|
Sheet metal pad type thermocouple_R990 series
Application: Boiler tube skin temperature
Heater tube and heater exchangers tube skin temperature
Other various tube wall temperature measurement
Element type: K, E, J, T, N
Accuracy: Standard : 0.75 % (for reading temp.)
Special : 0.4 % (for reading temp.)
Sheath outer diameters: 1.0, 1.6 ,3.2 and 4.8 mm
(*Double element is not 1.0 and 1.6 mm sheath outer diameter)
3.2 mm (Standard)
Pad and clip material: 316L SS
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R990
-Wise Control Vietnam
|
|
Thermocouple
|
Chordal type thermocouple_R980 series
Application: Boiler tube skin temperature
Other various tube wall temperature measurement
Element: K, E, J, T
Accuracy: Standard : 0.75 % (For reading temp.)
Special : 0.4 % (For reading temp.)
Sheath outer diameter (mm): 1.6, 2.3 and 3.2
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R980
-Wise Control Vietnam
|
|
Thermocouple
|
Explosion proof Non-metallic protection tube thermocouple_R970 series
Element: Type R (87 % Pt, 13 % Rh/Pt)
Type S (90 % Pt, 10 % Rh/Pt)
Type B (70 % Pt, 30 % Rh / 94 % Pt, 6 % Rh)
Type K
Tolerance on temperature reading "K" type : Class 2 (0.75 %)
Standard (0.75 %)
"R", "S" type : Class 2 (0.25 %)
Standard (0.5 %)
"B" type : Class 3 (0.5 %)
Standard (0.5 %)
Head material: ALDC (Standard)
316SS (Not available compact type)
Element outer diameter (mm): "K" type : 0.65, 1.0, 1.6, 2.3 and 3.2
"R", "S" and "B" type : 0.5
Certificates: KCS Ex d IIC T6 IP65
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R970
-Wise Control Vietnam
|
|
Thermocouple
|
Heavy duty type resistance temperature detector_R200
Element: Film sensor
Pt 100Ω at 0 ℃
TCR : 3,850 ppm/k
Tolerances on temperature reading: Class A : ± (0.15 + 0.002 l t l)
Class B : ± (0.3 + 0.005 l t l)
Head material: ALDC (Standard)
Temperature range: Class A : -60 ~ 250 ℃
Class B : -60 ~ 250 ℃
Sheath material: 316L SS
Sheath outer diameter: 6.4, 8.0 mm
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R200
-Wise Control Vietnam
|
|
Thermocouple
|
Cool-down and leak detector_R190 (RL series)
Junction box: 316SS
Element: Pt 100Ω at 0℃
Sheath material: 316L SS
Sheath outer diameter: 3.2, 4.8 and 6.4 mm
Temperature range: -200 ~ 100 ℃
Maximum measuring points: 15 points
Tolerances on temperature reading: Class A : ± (0.15 + 0.002 l t l)
Class B : ± (0.3 + 0.005 l t l)
Certificates: KCS Ex d IIC T6
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R190
-Wise Control Vietnam
|
|
Thermocouple
|
Sheathed thermocouple_R120 sereis (R series)
Element: K, E, J, T, N
Tolerances on temperature reading: Class 1, Class 2 (DIN/IEC584-2, BS/EN60584-2, JIS C1602)
Special, Standard (ASTM E230 E988 ISA-MC96.1)
Head material: ALDC (Standard)
304SS (Not available compact type)
316SS (Not available compact type)
Hot junction: shape Grounded Ungrounded
Sheath outer diameters: 1.0, 1.6, 2.3, 3.2, 4.8, 6.4, 8.0, 9.5 and 12.7 mm
Double element is not available for 1.0 and 1.6 mm sheath outer diameter
Certificates: KCS Ex d IIC T6
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R120
-Wise Control Vietnam
|
|
Thermocouple
|
Metallic protection tube thermocouple_R110 series
Element: K, E, J, T
Head material: ALDC (Standard)
304SS (Not available compact type)
316SS (Not available compact type)
Tolerances on temperature reading: Class 2 (DIN/IEC584-2, BS/EN60584-2, JIS C1602)
Standard (ASTM E230 E988 ISA-MC96.1)
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R110
-Wise Control Vietnam
|
|
Resistance Temperature Detector
|
Explosion proof Metallic protection tube thermocouple and RTD_R960 series
Element: Thermocouple : K, E, J, T, N
RTD : Pt 100 Ω at 0 ℃
Head material: ALDC (Standard) 316SS
Certificates: KCS Ex d e IIC T6 IP67
Tolerance on temperature reading: Thermocouple
Class 1, Class 2 (DIN/IEC584-2, BS/EN60584-2, JIS C1602)
Special, Standard (ASTM E230, E988, ISA-MC96.1)
RTD
Class A : ±(0.15 + 0.002 l t l)
Class B : ±(0.3 + 0.005 l t l)
Protecting tube outer diameter (RTD only): 6.4, 8.0 and 10mm
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R960
-Wise Control Vietnam
|
|
Resistance Temperature Detector
|
Intrinsic safety and increased safety type thermocouple and resistance temperature detector_R950 (ETR10 series)
Element: Thermocouple : K, E
RTD : Pt 100 Ω at 0 ℃
Standard nipple material: 304SS (Head type only)
Standard nipple length: 100 or 150 mm (Head type only)
Enclosure material: Die cast aluminium (ALDC) or 316SS (Head type only)
Standard measuring material: 316SS
Electrical rating: 10 mA 4 VDC resistance load
Standard process connection: ½" NPT
Ambient temperature: -40 ~ +65 ℃ (Ex ia) -40 ~ +65 ℃ (Ex e)
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R950
-Wise Control Vietnam
|
|
Resistance Temperature Detector
|
Explosion proof Thermocouple and resistance temperature detector_R940 series (ETR series)
Element: Sheath type
Thermocouple: K, E, J, T, N
RTD : Pt 100 Ω at 0 ℃
Non-metallic protection tube type
Type R (87 % Pt, 13 % Rh/Pt)
Type S (90 % Pt, 10 % Rh/Pt)
Type B (70 % Pt, 30 % Rh / 94 % Pt, 6 % Rh)
Type K
Head material ALDC (Standard) 316SS
Certificates: ATEX II 2G Ex d IIC T6 Gb IECEx Ex d IIC T6 Gb
Ambient temperature: -40 ~ +65 ºC
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R940
-Wise Control Vietnam
|
|
Resistance Temperature Detector
|
Explosion proof Multi point thermocouple and resistance temperature detector_R930 series (RC series)
Element: Thermocouple : K, E, J, T, N
R.T.D. : Pt 100 Ω at 0 ℃
Head material: Stainless steel Aluminium
Number of measuring temperature point: Possible to manufacture according to customer's require number of point within the allowed range of nozzle bore.
One thermocouple head could contain up to 5 points element.
Tolerances on temperature reading: Thermocouple
Class 1, Class 2 (DIN/IEC584-2, BS/EN60584-2, JIS C1602)
Special, Standard (ASTM E230 E988 ISA-MC96.1)
R.T.D.
Class A : ±(0.15 + 0.002 l t l)
Class B : ±(0.3 + 0.005 l t l)
Sheath outer diameter: Thermocouple 3.2, 4.8, 6.4 and 8.0 mm
R.T.D.
3.2, 4.8, 6.4 and 8.0 mm
Certificates: KCS Ex d IIC T6 IP67
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R930
-Wise Control Vietnam
|
|
Resistance Temperature Detector
|
Explosion proof type Sheathed thermocouple and resistance temperature detector with spring load_R921,R922 (RS series)
Element: Thermocouple : K, E, J, T, N
R.T.D. : Pt 100 Ω at 0 ℃
TCR : 3,850 ppm/k
Tolerances on temperature reading: Thermocouple
Class 1, Class 2 (DIN/IEC584-2, BS/EN60584-2, JIS C1602)
Special, Standard (ASTM E230 E988 ISA-MC96.1)
R.T.D.
Class A : ± (0.15 + 0.002 l t l)
Class B : ± (0.3 + 0.005 l t l)
Head material ALDC (Standard)
316SS
Sheath outer diameters: Thermocouple
1.0, 1.6, 2.3, 3.2, 4.8, 6.4, 8.0, 9.5 and 12.7 mm
* Double elements is not available for 1.0 and 1.6 mm sheath outer diameters
R.T.D.
3.2, 4.8, 6.4 and 8.0 mm
Certificates: KCS Ex d IIC T6 IP65
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R921, R922
-Wise Control Vietnam
|
|
Resistance Temperature Detector
|
Head mounting type temperature transmitter (RTD only)_R912 (with T990)
Electrical specification: Excitation voltage : 18 ~ 30 V
Load resistance : Max. 500 Ω at 24 V
Influence of excitation : 0.01 % FSO/V
Burnout : Upscale (Approx. 23 mA DC) or Down scale (Approx. 4 mA DC)
Reverse polarity : Protected
Shock resistance : No change in performance after 10Gs for 11ms
Vibration : 5g (10 ~ 2,000 Hz)
Response time (10 ~ 90 %) : ±0.5 seconds
Adjustment range : ±15 % of full scale / Zero and span
Performance specification: Accuracy : ±0.2 % of full scale
Non - linearity : Better than 0.10 % of full scale
Repeatability : Better than 0.05 % of full scale
Long term stability : Better than 0.05 % of full scale per month
Ambient temperature limits : -20 ~ 70 ℃
Ambient humidity limits : 5 ~ 95 % R.H
Input: Measuring element : Pt 100 Ω at 0 ℃
Output: Current output
Electrical connection type : 2-wire technique
Full scale output signal : 20 mA ±0.2 %
Zero measured output : 4 mA ±0.03 %
Other output signals available on request
Certificates: KCS Ex d IIC T6
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R912
-Wise Control Vietnam
|
|
Resistance Temperature Detector
|
Head mounting type multi temperature transmitter_R911 (with T900)
Electrical specification: Excitation voltage : 18 ~ 30 V DC
(Noise range:20 mVp-p)
Load resistance max : 600 Ω with 24 V
Influence of excitation : 0.01 % FSO/V
Reverse polarity : Protected
Shock resistance : No change in performance after 20Gs
Vibration : 0.1 g max.
Response time (10 ~ 90 %) : ±500 mSec. Adjustment range : Free
Performance specification: Accuracy : ±0.2 % FSO
Non - linearity : Better than 0.10 % FSO
Repeatability : Better than 0.05 % FSO
Long term stability : Better than 0.05% FSO per month
Cutoff frequency : ±1 kHz
Ambient temperature limits : -10 ~ 70 ℃
Ambient humidity limits : 10 to 90 % R.H
Input: Temperature sensor type : See table "Sensor type, range and accuracy"
Signal source : See table "Sensor type, range and accuracy"
Output: Current output : 4 ~ 20 mA loop powered
Electrical connection type : 2-wire technique
Full scale output signal : 20 mA ±0.2 %
Zero measured output : 4 mA ±0.03 %
Sensor burnout : High (20.5 mA DC) or Low (3.9 mA)
Certificates: KCS Ex d IIC T6
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R911
-Wise Control Vietnam
|
|
Resistance Temperature Detector
|
|
Coil End Temperature Detector and Bearing Temperature Sensor_R840 series
Element: RTD : Pt 100 Ω at 0 °C(DIN) Film type
Body material: Coil End Temperature Detector : Teflon Bearing
Temperature Sensor : 304SS, 316SS, 316L SS
Body outer diameter and length: Coil End Temperature Detector : Min. 4 x Min. 25 mm
Bearing Temperature Sensor : Min. 3.2 x Min. 6.35 mm
Molding: Coil End Temperature Detector : Silicone filled
Bearing Temperature Sensor : Epoxy filled, Silicon filled
Standard: Explosive atmospheres.
Equipment - General requirements
IEC 60079-0 / EN 60079-0
Electrical apparatus for explosive gas atmospheres.
Increased safety " e "
IEC 60079-7 / EN 60079-7
Intrinsic safety " i "
IEC 60079-11 / EN 60079-11
Certificates: ATEX II 2G Ex e IIC Gb
IECEx Ex e IIC Gb
ATEX II 1G Ex ia IIC T6...T3 Ga
IECEx Ex ia IIC T6...T3 Ga
Tolerances on temperature reading R.T.D.
Class A : ± (0.15 + 0.002 l t l)
Class B : ± (0.3 + 0.005 l t l)
Service Temperature (Ex e): -40 °C ≤ Tservice ≤ 180 °C
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R840
-Wise Control Vietnam
|
|
Resistance Temperature Detector
|
General type stator winding RTD_R830 series
Body material: High temperature epoxy glass
Temperature limit: Class F : 155 ℃ (311 ℉) Class H : 180 ℃ (356 ℉)
Lead wires: 3 wire or 4 wire, copper, AWG #22 (With FEP or polyimide insulation)
Ambient temperature: Tamb = -50 ~ 180 ℃
Working temperature: -50 ~ 180 ℃
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R830
-Wise Control Vietnam
|
|
Resistance Temperature Detector
|
Intrinsic safety type stator winding RTD_R820 series
Body material: High temperature epoxy glass
Temperature limit: Class F : 155 ℃ (311 ℉) Class H : 180 ℃ (356 ℉)
Lead wires: 3 wire or 4 wire, copper, AWG #22 (With FEP or polyimide insulation)
Ambient temperature: Tamb = -40 ~ 80 ℃ : T6
Tamb = -40 ~ 130 ℃ : T4
Tamb = -40 ~ 95 ℃ : T5
Tamb = -40 ~ 180 ℃ : T3
Working temperature: -50 ~ 180 ℃
Standard: Explosive atmospheres. Equipment. General requirements
■ IEC 60079-0 / EN 60079-0 : 2009
Electrical apparatus for explosive gas atmospheres. Intrinsic safety "i"
■ IEC 60079-11 / EN 60079-11 : 2007
Certificates: KCS Ex ia IIC T6...T3
ATEX II 1G Ex ia IIC T6...T3 Ga
IECEx Ex ia IIC T6...T3 Ga
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R820
-Wise Control Vietnam
|
|
Resistance Temperature Detector
|
Increased safety type stator winding RTD_R810 series
Body material: High temperature epoxy glass
Temperature limit: Class F : 155 ℃ (311 ℉)
Class H : 180 ℃ (356 ℉)
Lead wires: 3 wire or 4 wire, copper, AWG #22 (With FEP or polyimide insulation)
Ambient temperature: Tamb = -40 ~ 80 ℃ : T6
Tamb = -40 ~ 130 ℃ : T4
Tamb = -40 ~ 95 ℃ : T5
Tamb = -40 ~ 180 ℃ : T3
Working temperature: -50 ~ 180 ℃
Standard: Explosive atmospheres. Equipment. General requirements
■ IEC 60079-0 / EN 60079-0 : 2009
Electrical apparatus for explosive gas atmospheres. Increased safety "e"
■ IEC 60079-7 / EN 60079-7 : 2007
Certificates: KCS Ex e IIC Gb
ATEX II 2G Ex e IIC Gb
IECEx Ex e IIC Gb
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R810
-Wise Control Vietnam
|
|
Resistance Temperature Detector
|
Non-metallic protection tube thermocouple_R700 series
Element: Type R (87 % Pt, 13 % Rh / Pt)
Type S (90 % Pt, 10 % Rh / Pt)
Type B (70 % Pt, 30 % Rh / 94 % Pt, 6 % Rh)
Type K
Tolerances on temperature reading: "K" type : Class 2 (0.75 %)
Standard (0.75 %)
"R", "S" type : Class 2 (0.25 %)
Standard (0.5%)
"B" type : Class 3 (0.5 %)
Standard (0.5 %)
Head material: ALDC (Standard)
304SS (Not available compact type)
316SS (Not available compact type)
Element outer diameter: "K" type : 0.65, 1.0, 1.6, 2.3 and 3.2 mm
"R", "S", "B" type : 0.5 mm
Marker/ Origin: Wise Control_100% Korea Origin
|
Model R700
-Wise Control Vietnam
|
|
Switch/Recorder
|
Explosion proof type indicating temperature switch_T990
Ambient temperature: -20 ~ 60 °C
Nominal diameter: 125 mm
Repeatability: ±1.0 % of adjustable range
Accuracy: ±2.0 % of full scale
Measuring system (SAMA class ⅢB): Organic gas : 0 ~ 200 °C
Inert gas : -200 ~ 700 °C
Working range: Maximum scale value
Marker/ Origin: Wise Control_100% Korea Origin
|
Model T990
-Wise Control Vietnam
|
|
Switch/Recorder
|
Explosion proof temperature switch_T953 (953 series)
Repeatability: ±1.0 % of adjustable range
Dimension: Refer to type of mounting
Measuring system: Organic gas : 0 ~ 200 °C
Inert gas : -200 ~ 300 °C
Working range: Maximum scale value
Working temperature: Ambient : -40 ~ 65 °C
Marker/ Origin: Wise Control_100% Korea Origin
|
Model T953
-Wise Control Vietnam
|
|
Switch/Recorder
|
Weatherproof temperature switch_T941, T942
Dimension: Refer to type of mounting
Repeatability: ±1.0 % of adjustable range
Measuring system (SAMA class ⅢB): Organic gas : 0 ~ 200 °C
Inert gas : -200 ~ 700 °C
Dead band: One SPDT : 5 ~ 6 % of full scale
Two SPDT : 12 % of full scale
Working range: Maximum scale value
Marker/ Origin: Wise Control_100% Korea Origin
|
Model T941, T942
-Wise Control Vietnam
|
|
Switch/Recorder
|
Indicating temperature switch_T931 (Case compensation system SAMA class ⅢB) T932 (Full compensation system SAMA class ⅢA)
Nominal diameter: 150 mm
Repeatability: ±1.0 % of adjustable range
Accuracy: ±2.0 % of full scale
Measuring system: Organic gas : 0 ~ 200 °C (Only T932)
Inert gas : -200 ~ 700 °C
Working range: Maximum scale value
Marker/ Origin: Wise Control_100% Korea Origin
|
Model T931
-Wise Control Vietnam
|
|
Switch/Recorder
|
Temperature recorder (Case compensation system)_T930
Nominal diameter: 246 (W) x 271 mm (H)
Accuracy: ±2.0 % of full scale
Measuring system (SAMA class ⅢB): Organic gas : 0 ~ 200 °C
Inert gas : -200 ~ 700 °C
Working range: Maximum scale value
Marker/ Origin: Wise Control_100% Korea Origin
|
Model T930
-Wise Control Vietnam
|
http://www.wisecontrol.com/home/info/942
|
Thermowell
|
Vanstone type thermowell_A640 series
Selection of thermowell ■ Material
In general, the thermowell material chosen for the installation is governed mainly by the corrosion condition the thermowell will face. Recommended material for various services are given in the corrosion table. Occasionally, the material consideration is one of strength rather than corrosion. For example, a stainless steel thermowell may be required for a high pressure water service where otherwise a brass thermowell woule be satisfactory from a corrosion standpoint.
■ Insertion
The distance from the end of the well to the underside of the thread or other connection means (Designated as "U") is the insertion length.
■ Bore size
Almost any installation uses several type of temperature measuring instruments. The selection of a standard bore diameter can produce extreme flexibility within the plant.
■ Tapered or straight type
Tapered type thermowells provide greater stiffness for the same sensitivity. The higher strength to weight ratio gives these thermowells higher natural frequency than for equivalent length straight type thermowells, thus permitting operation at higher fluid velocity.
■ Option
Wake frequency calculations in accordance with ASME PTC 19.3
WISE Inc. offers this as an engineering service.
■ Standard "T" length
Well size 1½" or DN40 : 40 mm 2" or DN50 : 45 mm
Marker/ Origin: Wise Control_100% Korea Origin
|
Model A640
-Wise Control Vietnam
|
|
Thermowell
|
Bar stock thermowell with welded connection_A630, A631, A632
Selection of thermowell ■ Material
In general, the thermowell material chosen for the installation is governed mainly by the corrosion condition the thermowell will face. Recommended material for various services are given in the corrosion table. Occasionally, the material consideration is one of strength rather than corrosion. For example, a stainless steel thermowell may be required for a high pressure water service where otherwise a brass thermowell woule be satisfactory from a corrosion standpoint.
■ Insertion
The distance from the end of the well to the underside of the thread or other connection means (Designated as "U") is the insertion length.
■ Bore size
Almost any installation uses several type of temperature measuring instruments. The selection of a standard bore diameter can produce extreme flexibility within the plant.
■ Tapered or straight type
Tapered type thermowells provide greater stiffness for the same sensitivity. The higher strength to weight ratio gives these thermowells higher natural frequency than for equivalent length straight type thermowells, thus permitting operation at higher fluid velocity.
■ Option
Wake frequency calculations in accordance with ASME PTC 19.3
WISE Inc. offers this as an engineering service.
Marker/ Origin: Wise Control_100% Korea Origin
|
Model A630, A631, A632
-Wise Control Vietnam
|
|
Thermowell
|
Bar stock thermowell with flange connection_A610, A611, A612, A623
Selection of thermowell: ■ Material
In general, the thermowell material chosen for the installation is governed mainly by the corrosion condition the themowell will face. Recommended material for various services are given in the corrosion table.Occasionally, the material consideration is one of strength rather than corrosion. For example, a stainless steel thermowell may be required for a high pressure water service where otherwise a brass thermowell would be satisfactory from a corrosion standpoint.
■ Insertion
The distance from the end of the well to the underside of the thread or other connection means (Designated as "U") is the insertion length.
■ Bore size
Almost any installation uses several type of temperature measuring instruments. The selection of a standard bore diameter can produce extreme flexibility within the plant.
■ Tapered or straight type
Tapered type thermowells provide greater stiffness for the same sensitivity. The higher strength to weight ratio gives these thermowells higher natural frequency than for equivalent length straight type thermowells, thus permitting operation at higher fluid velocity.
■ Option
Wake frequency calculations in accordance with ASME PTC 19.3
WISE Inc. offers this as an engineering service.
Marker/ Origin: Wise Control_100% Korea Origin
|
Model A610, A611, A612, A623
-Wise Control Vietnam
|
|
Thermowell
|
Bar stock thermowell with thread connection_A600 series
Selection of thermowell: Material
In general, the thermowell material chosen for the installation is governed mainly by the corrosion condition the themowell will face. Recommended material for various services are given in the corrosion table. Occasionally, the material consideration is one of strength rather than corrosion. For example, a stainless steel thermowell may be required for a high pressure water service where otherwise a brass thermowell would be satisfactory from a corrosion standpoint.
■ Insertion
The distance from the end of the well to the underside of the thread or other connection means (Designated as "U") is the insertion length.
■ Bore size
Almost any installation uses several type of temperature measuring instruments. The selection of a standard bore diameter can produce extreme flexibility within the plant.
Marker/ Origin: Wise Control_100% Korea Origin
|
Model A600
-Wise Control Vietnam
|
|
Thermowell
|
Close end tube (Pipe) type thermowell_A500, A510 series
Selection of thermowell: ■ Material
In general, the thermowell material chosen for the installation is governed mainly by the corrosion condition the themowell will face. Recommended material for various services are given in the corrosion table. Occasionally the material consideration is one of strength rather than corrosion. For example, a stainless steel thermowell may be required for a high pressure water service where otherwise a brass thermowell would be satisfactory from a corrosion standpoint.
■ Insertion
The distance from the end of the well to the underside of the thread or other connection means (Designated as "U") is the insertion length.
■ Tapered or straight type
Tapered type thermowells provide greater stiffness for the same sensitivity. The higher strength to weight ratio gives these thermowells higher natural frequency than for equivalent length straight type thermowells, thus permitting operation at higher fluid velocity.
■ Bore size
Almost any installation uses several types of temperature measuring instruments. The selection of a standard bore diameter can produce extreme flexibility within the plant.
Marker/ Origin: Wise Control_100% Korea Origin
|
Model A500, A510
-Wise Control Vietnam
|
|
Thermowell
|
Sanitary thermowell (3-A marking)_A603
Process connection: Tri-clamp connection 1S, 1½S and 2S
Gauge connection: ½" (N)PT, female
Bore diameter: 7, 9, 10 and 12 mm
Material: 304SS, 316SS and 316L SS
Surface finish: Max. Ra 32 µin. (0.8 µm)
Marker/ Origin: Wise Control_100% Korea Origin
|
Model A603
-Wise Control Vietnam
|
|