Đại lý Noeding Vietnam,Noeding Vietnam - ANS Vietnam
ĐẠI LÝ NOEDING VIETNAM
Five decades Nöding Meßtechnik
1958 - 2019
The company was founded in 1958 by Mr. Gustav Noeding and focussed initially on commercializing revolution counters and gauges with electrical contacts. In-house design and production of temperature instruments and controllers, transmitters and isolation amplifiers was introduced as a natural developement of the company.
In 1987 Ralf Noeding took over from his father and the company was converted into Noeding Messtechnik GmbH, a limited liability company.
The markets showed in the last decades an ever increasing requirement for pressure measurement. As a logical consequence, Noeding Messtechnik specialized in the design and production of pressure transmitters. In 2001 the company relocated to a new facility, where today substantial quantities of transmitters are being produced for OEMs, endusers, retailers etc..
1. PRESSURE TRANSMITTER:
Safety note:
The pressure transmitter is designed for measuring absolute and gauge pressure of gases, vapours and liquids. If used incorrectly, application related dangers may arise. The transmitter must be installed, connected, commissioned, operated and maintained only by qualified and authorised personnel and under strict observance of these operating instructions, relevant national standards, legal requirements, and where appropriate, the product certification.
Installation:
The function of the transmitter is nearly independent of its orientation. To protect the process connection and pressure diaphragm from damage, remove the protective cap just before installation. The pressure transmitter must be installed in accordance with applicable national guidelines for pressure components. We recommend the use of isolating valves, syphons etc.. During installation, ensure that no water enters the housing.
P20-HB1-1111
Ranges
60 mbar - 20 bar
Process connection
G 1/2" flush mounted
Output
4...20mA
Accuracy
0,3 %
P115-400-G161-1
Ranges
100 mbar - 300 mbar
Process connection
G 1/2"
Output
4...20 mA
Accuracy
0,5 %
P120.01-403-F3A
Ranges
20 mbar - 60 bar
turndown 3:1
Process connection
G 1/2", 1/2 NPT
Output
0(4)...20mA, 0...10V
Accuracy
0,2 %
P121-400-G17
Ranges
40 mbar - 250 bar
Process connection
G 1/4", G 1/2"
1/4 NPT, 1/2 NPT
Output
4...20mA, 0...10V
Accuracy
0,2 %, 0,1 % optional
P131-4B0-V17
Ranges
40 mbar - 60 bar
Process connection
flush mounted
Output
4...20 mA, 0...10 V
Accuracy
0,2 %, 0,1 % optional
P136-401-F31
Ranges
10 mbar - 60 bar
turndown 5:1
Process connection
flush mounted
Output
4...20 mA
Accuracy
0,2 %
P136-402-F31
Ranges
10 mbar - 60 bar
turndown 5:1
Process connection
flush mounted
Output
4...20 mA
Accuracy
0,2 %
PD41.01-4PY2-R1H-H0
Range
50 mbar - 25 bar
max. pressure 250 bar
Process connection
1/4-18 NPT
Output
4...20 mA
Accuracy
0,2 %
PDM80 -2510 – 011
Range
25 mbar - 60 bar
Process connection
G 1/4"
Output
0(4)...20mA, 0...10V
Accuracy
0,2 %
2. DEGITAL PRESSURE GAUGE
Safety notes:
The digital contact pressure gauge is designed for measuring absolute and gauge pressure of gases, vapours and liquids. If used incorrectly, application related dangers may arise. The transmitter must be installed, connected, commissioned, operated and maintained only by qualified and authorised personnel and under strict observance of these operating instructions, relevant national standards, legal requirements, and where appropriate, the product certification.
Installation:
The function of the transmitter is nearly independent of its orientation. To protect the process connection and pressure diaphragm from damage, remove the protective cap just before installation. The pressure transmitter must be installed in accordance with applicable national guidelines for pressure components. During installation, ensure that no water enters the housing.
PM82-0110-330
Range
500 mbar - 250 bar
Process connection
G1/2 B
Output
0(4)...20mA, 0...10V
DC PNP 200mA
Accuracy
0,5 %
PM82-3110-330
Range
500 mbar - 250 bar
Process connection
G1/2 B
Output
0(4)...20mA, 0...10V
DC PNP 200mA
Accuracy
0,5 %
PM82-4-01-HD-330
Range
500 mbar - 250 bar
Process connection
G1/2 B
Output
0(4)...20mA, 0...10V
DC PNP 200mA
Accuracy
0,5 %
=====================================================